🎛️ Testing Control Relays
Guide to diagnosing relay problems in parking access control systems.
What is a Relay?
A relay is an electrically operated switch that uses a small control current to switch a larger power current. Common in gate controllers, barrier operators, and access control systems.
Relay Components
- Coil: Electromagnet activated by control voltage (usually 12V or 24V DC)
- Contacts: Switching mechanism (NO = Normally Open, NC = Normally Closed, COM = Common)
- Armature: Moving part that changes contact position
Testing Methods
Test 1: Visual Inspection
- Power off system
- Inspect relay for:
- Burn marks or discoloration
- Melted plastic
- Loose or corroded terminals
- Damage to socket
- If visible damage, replace relay
Test 2: Listen for Click
- Power on system
- Activate relay (press button, trigger input, etc.)
- Listen for audible "click" sound
- Click indicates coil energizing and contacts moving
- No click = bad relay or no coil voltage
Test 3: Measure Coil Voltage
- Set voltmeter to DC voltage
- Identify coil terminals (usually labeled or shown in diagram)
- Measure voltage across coil terminals
- Should read rated voltage when activated (12V, 24V, etc.)
- No voltage = control circuit problem, not relay
- Correct voltage but no click = failed relay coil
Test 4: Check Contact Continuity
- Power off system
- Remove relay from socket
- Set multimeter to continuity/ohms
- Test between COM and NO: Should read OPEN (infinite resistance)
- Test between COM and NC: Should read CLOSED (0-1 ohm)
- Apply voltage to coil (use separate power supply)
- Contacts should change state (NO closes, NC opens)
- If contacts don't change, relay is bad
Test 5: Measure Contact Voltage
- Power on system
- Measure voltage at relay COM terminal
- Should read input voltage (often 120V AC or 24V DC)
- Activate relay
- Measure voltage at NO terminal
- Should now read same voltage as COM
- No voltage at NO when activated = bad contacts
Common Relay Problems
Relay Clicks But Nothing Happens
- Burned or pitted contacts
- Contacts not making good connection
- High resistance in contacts
- Solution: Replace relay
No Click, Has Coil Voltage
- Burned out relay coil
- Broken armature
- Mechanical obstruction
- Solution: Replace relay
No Click, No Coil Voltage
- Problem in control circuit
- Bad controller output
- Broken wire to relay coil
- Solution: Trace control circuit back to source
💡 Pro Tip: Always keep spare relays on hand. They're inexpensive and quick to replace. Most parking systems use standard SPDT or DPDT relays available at any electrical supplier.